Deye 48V ,5kw 6kw .8kw 10kw 12kw hybrid solar inverter with MPPT trackers
Model
|
SUN-5K
-SG04LP3-EU |
SUN-6K
-SG04LP3-EU |
SUN-8K
-SG04LP3-EU |
SUN-10K
-SG04LP3-EU |
SUN-12K
-SG04LP3-EU |
Battery Input Data
|
|||||
Battery Type
|
Lead-acid or Li-lon
|
||||
Battery Voltage Range (V)
|
40~60
|
||||
Max. Charging Current (A)
|
120
|
150
|
190
|
210
|
240
|
Max. Discharging Current (A)
|
120
|
150
|
190
|
210
|
240
|
External Temperature Sensor
|
Yes
|
||||
Charging Curve
|
3 Stages / Equalization
|
||||
Charging Strategy for Li-Ion Battery
|
Self-adaption to BMS
|
||||
PV String Input Data
|
|||||
Max. DC Input Power (W)
|
6500
|
7800
|
10400
|
13000
|
15600
|
Rated PV Input Voltage (V)
|
550 (160~800)
|
||||
Start-up Voltage (V)
|
160
|
||||
MPPT Voltage Range (V)
|
200-650
|
||||
Full Load DC Voltage Range (V)
|
350-650
|
||||
PV Input Current (A)
|
13+13
|
26+13
|
|||
Max. PV I (A)
|
17+17
|
34+17
|
|||
No.of MPP Trackers
|
2
|
||||
No.of Strings per MPP Tracker
|
1
|
2+1
|
AC Output Data
|
|||||
Rated AC Output and UPS Power (W)
|
5000
|
6000
|
8000
|
10000
|
12000
|
Max. AC Output Power (W)
|
5500
|
6600
|
8800
|
11000
|
13200
|
AC Output Rated Current (A)
|
7.6/7.2
|
9.1/8.7
|
12.1/11.6
|
15.2/14.5
|
18.2/17.4
|
Max. AC Current (A)
|
11.4/10.9
|
13.6/13
|
18.2/17.4
|
22.7/21.7
|
27.3/26.1
|
Max. Continuous AC Passthrough (A)
|
45
|
||||
Peak Power (offff grid)
|
2 time of rated power, 10 S
|
||||
Power Factor
|
0.8 leading to 0.8 lagging
|
||||
Output Frequency and Voltage
|
50/60Hz; 3L/N/PE 220/380, 230/400Vac
|
||||
Grid Type
|
Three Phase
|
||||
DC injection current (mA)
|
THD<3% (Linear load<1.5%)
|
||||
Effiffifficiency
|
|||||
Max. Effiffifficiency
|
97.60%
|
||||
Euro Effiffifficiency
|
97.00%
|
||||
MPPT Effiffifficiency
|
99.90%
|
||||
Protection
|
|||||
Integrated
|
PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection,
Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection,Output Shorted Protection, Surge protection
|
||||
Output Over Voltage Protection
|
DC Type II/AC Type III
|
||||
Certififications and Standards
|
|||||
Grid Regulation
|
CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98,
VDE 0126-1-1, RD 1699, C10-11
|
||||
Safety EMC / Standard
|
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
|
General Data
|
||||
Operating Temperature Range (℃)
|
-40~60℃, >45℃ derating
|
|||
Cooling
|
Smart cooling
|
|||
Noise (dB)
|
<45 dB
|
|||
Communication with BMS
|
RS485; CAN
|
|||
Weight (kg)
|
33.6
|
|||
Size (mm)
|
422W x 699.3H x279D
|
|||
Protection Degree
|
IP65
|
|||
Installation Style
|
Wall-mounted
|
|||
Warranty
|
5 years
|